Search For:

CEM SPECIALTIES INC.
1100 Dearness Drive
London, Ontario
Canada N6E 1N9
Tel: 519-681-9595
Fax: 519-681-8799
Toll Free: 1-866-236-7732
admin@cemsi.on.ca

Map to Company
|
PRODUCTS
- Particulate Monitors

Back to Products
DURAG
D-R 300
- Soot Monitor
D-R 300-40
- Dust Concentration Monitor
D-R 800
- Dust Concentration Monitor
D-RX 250 -
Combined Monitor (Dust, Flow, Pressure and
Temperature)
F-904
- Beta Gauge Particulate Monitor
F-904-K
- Beta Gauge Particulate Monitor
OF-1200
- Soot Monitor (Emission)
OF-1200i
- Soot Concentration Monitor (Ambient Air)
D-R 300
- Soot Monitor
|
Description: |
The
D-R 300 works according to the back
scattering principle and has been
designed to monitor extremely low
soot concentrations in light oil
fired plants. |
|
Applications: |
Measurement of lowest soot
concentrations |
|
Sensitivity: |
5 µg/m3 |
|
Compliance: |
TÜV approved |
|
Measuring range: |
Smallest
measuring range 0 3 soot number,
lowest detection limit 0,005
mg/m3
|
|
Flue gas temperature: |
Above dew point, up to 320°C,
higher on request |
|
Accuracy: |
< 2% FS |
|
Measured components: |
Stray light
intensity / soot number |
|
Measuring principle: |
Back
scattering
|
|
Measuring output: |
2 analog outputs 0/4...20 mA |
|
Protection:
|
IP 65 |
|
Ambient temperature: |
-20°... +50°C |
|
Status/control signals: |
Relay outputs and potential free
inputs for status signals |
|
System components: |
Transmitter/Receiver unit, 2 light
traps, control unit, one purge air
blower |
|
Test functions: |
Automatic zero and span check point |
|
Download: |
DR300 Brochure |
D-R 300-40
- Dust Concentration Monitor
|
Description: |
The
D-R 300-40 works according to the
back scattering principle and has
been designed to monitor extremely
low dust concentrations in various
application processes like
incinerators, steelworks, cement
plants etc. TÜV approved
according to German Clean Air Act,
large combustions and waste
incinerators. |
|
Applications: |
Measurement of lowest dust
concentrations |
|
Sensitivity: |
0.01 mg/m3 |
|
Compliance: |
TÜV approved
for quantitative emissions monitoring,
especially for waste incinerators, GOST |
|
Measuring range: |
Smallest
measuring range 0...1 mg/m3,
largest range 0...100 mg/m3
|
|
Flue gas temperature: |
Above dew point, up to 320°C,
higher on request |
|
Accuracy: |
< 2% FS |
|
Measured components: |
Stray light
intensity / dust concentration |
|
Measuring principle: |
Back
scattering
|
|
Measuring output: |
2 analog outputs 0/4...20 mA |
|
Protection:
|
IP 65 |
|
Ambient temperature: |
-20°... +50°C |
|
Status/control signals: |
Relay outputs and potential free
inputs for status signals |
|
System components: |
Transmitter/Receiver unit, light
trap, control unit, one purge air
blower |
|
Test functions: |
Automatic zero and span check point |
|
Download: |
DR300 Brochure |
D-R 800
- Dust Concentration Monitor
|
Description: |
 Where
other technologies fail, the D-R 800
measures precisely even lowest dust
concentrations by means of scattered
light principle integrated into a
measuring lance. Mechanical
adjustment and alignment on dust
free measuring section are not
necessary.
|
|
Applications: |
Monitoring minimal dust concentrations |
|
Measuring range: |
0...10/200 mg/m3
|
|
Flue gas temperature: |
Above dew point, up to 220°C, higher
on request
|
|
Accuracy: |
2% of measuring range |
|
Measured components: |
Stray light intensity / dust
concentration in mg/m3 |
|
Measuring principle: |
Forward scattering
|
|
Measuring path: |
Stack wall thickness < 0.4 m |
|
Measuring output: |
0/4...20 mA analog output |
|
Interfaces: |
RS 485 Modbus RTU |
|
Protection:
|
IP 65 |
|
Ambient temperature: |
-20°... +50°C |
|
Status/control signals: |
relay outputs and potential free
inputs for status signals
|
|
System components: |
Transmitter/Receiver unit, control
unit, connection box with blower |
|
Test functions: |
Automatic zero and span check point |
|
Download: |
DR800 Brochure |
D-RX 250
-
Combined Monitor (Dust, Flow, Pressure and
Temperature)
|
Description: |
 Single-rod
measurement probe for the
simultaneous measurement of: Dust
concentration [mg/Nm3],
Volume flow [Nm3/h],
Temperature [°C], Absolute pressure
[hPa]; Only one probe /
mounting aperture in flue-gas duct
Operation and evaluation unit can be
connected at up to 1000 m distance via
bus interface; For measurements
according to the TA Luft emission
standard, 13., 17. and 27. BImSchV. |
|
Applications: |
Continuous
measurement of dust, flow, temperature
and pressure behind filtering systems |
|
Compliance: |
TÜV
approved for qualitative emissions
monitoring |
|
Measuring range: |
Dust concentration: 0...10
up to 0...500 mg/Nm3; Volume flow
0...999.999 Nm3/h; Temperature:
0...300°C; Pressure: 900...1.300 hPa |
|
Flue gas temperature: |
Above
dew point, up to 200°C, higher on
request |
|
Measured components: |
Dust
concentration in mg/m3
or mg/Nm3;
Volume flow in m3/h
or Nm3/h;
Temperature in °C; Pressure in hPa |
|
Measuring principle: |
Tribo electric +
differential pressure
|
|
Measuring path: |
> 0.3 m |
|
Measuring output: |
4 analog
outputs 0/4...20 mA, variable
assignment |
|
Interfaces: |
RS485 Modbus RTU |
|
Protection:
|
IP 65
|
|
Ambient temperature: |
-20°...
+50°C |
|
Status/control signals: |
relay
outputs for status signals |
|
System components: |
Probe,
transmitting and operation unit and
differential pressure transformer |
|
Test functions: |
Automatic zero and span check point |
|
Download: |
DRX250
Brochure |
F-904
- Beta Gauge Particulate Monitor
|
Description: |
The
F-904 is an extractive Dust
Concentration Monitor for
measurement/monitoring of dust
concentrations in industrial plants.
It has been designed especially for
wet stack gases. With a heated
sampling system the sample gas will
be
sucked and the dust sampled on a
filter tape. The dilution of the
sample gas allows to measure high
dust concentrations. |
|
Applications: |
Coal and oil
fired power plants, waste incinerators
and waste water sludge incinerators,
measurement/monitoring of dust
concentration after wet scrubbers, in
very wet waste gases in other process
applications, heavy metal analysis,
measurement of dust concentration in a
large range, sampling points on limited
mounting positions and small stack
diameters; Measurement of Dust
Concentration in wet gases. |
|
Sensitivity: |
< 0,3
mg/Nm3 |
|
Compliance: |
German
equivalency test for all burners
incl. waste incinerators, Korean MOE
approved |
|
Measuring range: |
Dust
concentration: 0...1 up to 0...2000
mg/Nm3
|
|
Flue gas temperature: |
low
(below dew point) and high
temperatures |
|
Accuracy: |
5% of
measuring range |
|
Measured components: |
Dust
concentration in mg/Nm3,
gas sample dry, temperature in °C |
|
Measuring principle: |
Absorption
of Beta-radiation |
|
Measuring output: |
Analog
outputs: 4...20 mA for dust
concentration (variable range
assignment) and dust mass (fixed
assignment) |
|
Interfaces: |
Analog
outputs, digital status signals
(inputs, outputs) |
|
Protection:
|
IP 54
|
|
Ambient temperature: |
0°...50°C |
|
Status/control signals: |
relay
outputs and inputs for status
signals |
|
System components: |
Sample
probe, Sample line, measuring
instrument |
|
Test functions: |
Automatic zero and span
check point, reference foil |
|
Download: |
F904 Brochure |
F-904-K
- Beta Gauge Particulate Monitor
|
Description: |
The
F-904's major components are housed
in a sturdy cabinet and are easily
accessible for periodic inspection
and maintenance. The Model
F-904-K Extractive Beta Gauge
Particulate Monitor is designed for
a wide range of emission monitoring
applications. |
|
Applications: |
Coal and oil
fired power plants, waste incinerators
(urban, industrial and hazardous waste), waste water sludge incinerators,
dust monitoring after wet scrubbers, heavy metal analysis,
small diameter stack monitoring,
particulate monitoring in process
applications (bag houses, etc.);
transportable version for mobile
applications. |
|
Download: |
F904K Brochure |
OF-1200
- Soot Monitor (Emission)
|
Description: |
The
OF-1200 is a Soot Meter, based on
sampling of soot particles on a
filter tape in a sample gas volume
of an emission and measurement of
optical reflection. It has
been designed to monitor soot
concentrations in light oil fired
plants.
|
|
Applications: |
Measurement
of soot concentrations in emission |
|
Sensitivity: |
0.1 RZ
|
|
Compliance: |
German
equivalency test according to TA Luft
|
|
Measuring range: |
0...3 RZ |
|
Flue gas temperature: |
Low
(below dew point) and high
temperatures |
|
Accuracy: |
< 5% of
measuring range |
|
Measured components: |
Smoke spot
number RZ |
|
Measuring principle: |
Differential
optical reflection of a filter before
and after sampling of soot |
|
Measuring output: |
Analog
output 4...20 mA for Rußzahl RZ (fixed
assignment) |
|
Interfaces: |
RS 232,
device interface (analog outputs,
digital status inputs and outputs) |
|
Ambient temperature: |
0°...50°C |
|
Status/control signals: |
Relay
outputs and inputs for status
signals |
|
System components: |
Sampling
system (inlet, sample line),
measuring instrument |
|
Test functions: |
Automatic
zero check point, reference foil |
|
Download: |
OF1200i Brochure |
OF-1200i
- Soot Concentration Monitor (Ambient Air)
|
Description: |
The
OF-1200i is a Soot Concentration
Meter, based on sampling of soot
particles on a filter tape in a
sample gas volume of the ambient air
and measurement of optical
reflection.
|
|
Applications: |
Measurement/monitoring of soot
concentrations in the ambient air
|
|
Sensitivity: |
< 0.2 µg/m3
(1h-suck cycle) |
|
Compliance: |
Conforms to
TA-Luft |
|
Measuring range: |
0...360 µg/m3 |
|
Flue gas temperature: |
Ambient
temperature |
|
Measured components: |
Smoke spot
number RZ |
|
Measuring principle: |
Differential
optical reflection of a filter before
and after sampling of soot
|
|
Measuring output: |
Analog
output 4...20 mA for soot
concentration 0...360 µg/m3 (fixed
assignment) |
|
Interfaces: |
RS 232,
device interface (analog outputs,
digital status inputs and outputs) |
|
Ambient temperature: |
0°...50°C |
|
Status/control signals: |
Relay
outputs and inputs for status
signals |
|
System components: |
Sampling
system (inlet, sample line),
measuring instrument |
|
Test functions: |
Automatic
zero check point, reference foil |
|
Download: |
OF1200i Brochure |
Top
of Page |
Shortcuts

CEM SYSTEMS

PROCESS
ANALYTICS

SERVICES

APPLICATIONS QUESTIONNAIRE |