PRODUCTS - Gas Sample Probe Tubes

Back to Products


Behind Wet Scrubber
Dust Loadings Less Than 2 g/m³
Dust Loadings Greater Than 2 g/m³
Very High Dust Loadings

M&C Products

Behind Wet Scrubber:

The M&C sample tubes are used in combination with the M&C gas sample probes series SP for point selective continuous gas sampling in processes with low dust loadings.

SP2000/SP32 - PVDF, with demister, up to max. 90°C.
Download
SP2000ss Data Sheet
 

Dust Loadings Less Than 2 g/m³:

The M&C sample tubes are used in combination with the M&C gas sample probes series SP for point selective continuous gas sampling in processes with low dust loadings.

SP210/SS - Stainless steel, up to max. 600°C , for SP210-H and SP210H/W.
Download
SP2000ss Data Sheet

SP2000/SS - Stainless steel, up to max. 600°C.
Download
SP2000ss Data Sheet

SP2000/SS Vm - Stainless steel with volume displacer, up to max. 600°C.
Download
SP2000ss Data Sheet
 

SP2000/PV
- PVDF, up to max. 90°C.
Download
SP2000ss Data Sheet

SP2000/T - PTFE, up to max. 160°C.
Download
SP2000ss Data Sheet

SP2000/Ti - Titanium, up to max. 400°C.
Download
SP2000ss Data Sheet

SP2000/HC - Hastelloy, up to max. 900°C.
Download
SP2000ss Data Sheet

Dust Loadings Greater Than 2 g/m³:

The M&C pre-filters are used in combination with the M&C gas sample probes series SP for continuous gas sampling in processes with high dust content.

SP2000/V20 - Stainless steel pre-filter, up to max. 600°C, in different executions.
Download
SP2000 V20 Data Sheet

SP2000/20SS 150 - Stainless steel pre-filter for retrofitting the SP2000 stainless steel tube, up to max. 600°C.
Download
SP2000 V20 Data Sheet

SP2000/V20HC - Hastelloy pre-filter, up to max. 900°C, in different executions.
Download
SP2000 V20 Data Sheet

Very High Dust Loadings:

The M&C pre-filters are used in combination with the M&C gas sample probes SP series  for continuous gas sampling in processes with high dust content.

SP2000/V20T - Pre-filter with PTFE-hose, up to max. 200°C. Due to its excellent property of back purging and a reduced surface resistance, the pre-filter V-20T is particularly suitable for gas sampling in coal bunkers with its high content of fine dust.
Download
SP2000 V20 Data Sheet

SP2000/V12 - Ceramic pre-filter, up to max. 1000°C, in different executions.
Download
SP2000 V20 Data Sheet

SP2000/V12SS
- Ceramic pre-filter with stainless steel protection tube, up to max. 600°C, in different executions.
Download
SP2000 V20 Data Sheet

SP2000/V12IC - Ceramic pre-filter with Inconel protection tube, up to max. 1000°C, in different executions.